- Meeting abstract
- Open access
- Published:
Volar plating of dorsal PIPJ fracture-dislocations
BMC Proceedings volume 9, Article number: A47 (2015)
Fracture-dislocations of the proximal interphalangeal joint (PIPJ) remains a challenging injury to manage. For those that are unstable, a variety of surgical treatment have been reported, each with its pros and cons:
-
1.
Open reduction and internal fixation, with
-
a.
Interfragmentary screws from either the dorsal or volar approach,
-
b.
Cerclage wiring
-
2.
Hemi-hamate osteochondral grafting, using fixed with interfragmentary screws,
-
3.
Volar-plate arthroplasty,
-
4.
Hemi-arthroplasty replacement.
Volar plating of dorsal fracture-dislocation of the PIPJ with mini-T or hook plates ensures secure fixation and allows early mobilization with good results. This technique is also applicable when the volar fragment is comminuted.
The surgical technique of volar plating with mini-C arm guidance is as follows:
-
1.
exposure through A3 pulley
-
2.
mobilization of volar fragment attached to volar plate
-
3.
dorsal blocking wire to reduce and hold joint in place
-
4.
elevation of any depressed articular fragment and bone grafting
-
5.
repositioning of volar fragment over the base of middle phalanx
-
6.
preliminary fixation with K wire
-
7.
plating with mini 1.2 or 1.3mm T plate, or hook plate(s)
-
8.
removal of dorsal block wire if stable
Figure 1
Early range of motion exercise regime is started. A resting gutter splint is applied to prevent flexion contracture of the PIPJ.
References
Chew WYC, Cheah AEJ: Volar plate and screw fixation for dorsal fracture-dislocation of the proximal interphalangeal joint: case report. J Hand Surg. 2010, 35 (6): 928-930. 10.1016/j.jhsa.2010.02.011.
Cheah AE, Tan DM, Chong AK, Chew WY: Volar plating for unstable proximal interphalangeal joint dorsal fracture-dislocations. J Hand Surg Am. 2012, 37 (1): 28-33.
Author information
Authors and Affiliations
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
About this article
Cite this article
Chong, W.C.Y. Volar plating of dorsal PIPJ fracture-dislocations. BMC Proc 9 (Suppl 3), A47 (2015). https://doiorg.publicaciones.saludcastillayleon.es/10.1186/1753-6561-9-S3-A47
Published:
DOI: https://doiorg.publicaciones.saludcastillayleon.es/10.1186/1753-6561-9-S3-A47